• Corporate Profile
  • Products & Services
  • Investor Relation
  • Contact us
for Machine Vision for Machine Vision

for Machine Vision

Information on New Products and Popular Products

Introducing newly developed products by combining the technology of CCS.

Click here to download documents.
  • BB series
  • Product Summary
  • Expandability
  • Field Adaptability
  • Operability
  • Flexibility
  • Specifications / Dimensions
Building Block Power Supply that Pursues
*Building block system:
A method of configuring a system in the same manner as piling up blocks through the selection and combination of units.

Lineup introduction
Master unit
Master unit

Unit provided with setting and control functions.
This controls all connected units.
Constant lighting and strobe lighting types are available.
You can choose from either 12V or 24V output types depending on the type of lighting to be connected.

Modelname
Constant lighting Strobe lighting
Slave unit
Slave unit

Unit designed for expanding lights. This can be added and connected depending on the number of lights you use.
Constant lighting and strobe lighting types are available. You can choose from either 12V or 24V output types depending on the type of lighting to be connected.

Modelname
Constant lighting Strobe lighting
Interface unit
Interface unit

Unit for external control provided with a parallel communication function.
CMOS input and photocoupler input types are available.

CMOS Photo coupler

Description of model names
  • *1)Our LED light is available in 12V input and 24V input types. Please select either of these types depending on the type of light you intend to use.
  • *2)The constant lighting type enables the setting of intensity in 256 steps (light control) through PWM (Pulse Width Modulation) control. The strobe lighting type is specified for overdrive, and can be set to lighting times ranging from 0.001 to 1ms.
  • *3)The CMOS input type performs external control input and output using CMOSs in the same manner as our PD2 series digital power supplies. The photocoupler input type performs external control input and output using photocouplers.
Expandability Lineup of 3 units and 10 models 1 Realizes a wide variety of system configurations through the selection and combination of units
Lineup of 3 master, slave, and interface units, and 10 models.
2 Easy addition and expansion of functions
Comprehensive lighting control systems with multiple functions can be configured by adding units.
3 Units with different specifications can be integrated by a master unit
You can choose either constant lighting or strobe lighting types for master and slave units.
(A maximum of 18 units can be connected: 1 master unit, 15 slave units, and 2 interface units)
4 Flexibly corresponds to changes of inspection environments through the addition of slave units
The addition of lights due to changes of inspection environments can be flexibly handled through the addition of slave units.
5 Controls more than one lighting unit through interface units
Interface units (parallel communication function) can be selected from either CMOS input or photo-coupler input types.
(A maximum of eight slave units can be controlled through communication.)
Field adaptability Adaptable to field environments 1 DIN rail mounting suitable for installation environments
Can be installed on DIN rails in a single operation without the need for screws or tools.
2 DC24V input specification suitable for power source environments
Control operations can be integrated with DC24V inputs in common with machine vision equipment.
3 Simple wiring and easy maintenance
Can be connected to interface units (parallel communication function) through a single cable. Also connected to other units via the coupling connector of the main body, which eliminates extra wiring.
4 Space-saving compact design
Compact bodies has realized weight reductions. In addition, a compact design contributes to space-saving installation.
5 Unified design and size
Unification of design and body size with other units improves operability and maintenance performance.
Operability Easy operation enables smooth working on site. 1 Centralized control by a master unit
A wide variety of setting and control functions are integrated into the master unit. Connected units can be identitied by ID numbers.
2 One-touch operation
Units can be operated using panel buttons. Reliable setting using one-touch operation has improved operability.
3 Improved reproducibility and visibility
Digital displays provide clear readings at a glance. Operation conditions can be checked and setting values can be controlled easily.
4 Set-data Protection
A locking function is employed in order to prevent set values from being change. Data is reliably protected allowing for the maintenance only by authorized operators.
5 Error display function
When any errors occur, details are displayed on the display panel, allowing for the early implementation of countermeasures.
Flexibility Operation function can be selected to suit specific environments. 1 Flexible selection of operation functions
The lighting mode can be selected and the lighting frequency and signal logic can be changed for the constant lighting type.
Pulse width and delay time can be set and signal logic can be changed for the strobe lighting type.