• Corporate Profile
  • Products & Services
  • Investor Relation
  • Contact us
for Machine Vision for Machine Vision

for Machine Vision

Information on New Products and Popular Products

Introducing newly developed products by combining the technology of CCS.

Click here to download documents.
  • HLND-SW2
  • Product Summary
  • Specifications / Dimensions
Specifications & Dimensions(mm)
Specifications
Model HLND-△△△SW2-□
△△△
Apply figures (in the range of 100 to 2,700) to this portion according to the length of light emitting surface.
LED Color white
T
R
Type back-light front-light
Peak Wavelength /
Color Temp.
typ. 6500K
Half radius of emission wavelength -
Connector Metal connector(7 pins,male)
Polarity and Signal 1,2,3:(+) 4,5,6:(-) 7:NC
Cooling Method Natural air cooling
Housing material Aluminum
Operating Environment Temp.: 0 to 40 C, Humidity: 20 to 85%RH
(With no condensation)
Storage Environment Temp.:-20to 60 C, Humidity: 20 to 85%RH
(With no condensation)
Laser Class Class-2 LED : Do not stare into the light beam.
Dimensions(mm)
Dimensions
Specifications/Dimensions of Linelights for All Sizes
Light Emitting Surface Model Type Power Consumption Applicable outline dimensions Weight
n A B
100mm HLND-100SW2 T(back-light)
/
R(front-light)
10W 1 156.3 100 520g
200mm HLND-200SW2 20W 2 256.3 200 840g
300mm HLND-300SW2 30W 3 356.3 300 1,160g
600mm HLND-600SW2 60W 6 656.3 600 2,120g
900mm HLND-900SW2 91W 9 956.3 900 3,080g
1,200mm HLND-1200SW2 107W 12 1,256.3 1,200 4,040g
1,500mm HLND-1500SW2 133W 15 1,556.3 1,500 5,000g
1,800mm HLND-1800SW2 160W 18 1,856.3 1,800 5.960g
2,100mm HLND-2100SW2 186W 21 2,156.3 2,100 6,920g
2,400mm HLND-2400SW2 213W 24 2,456.3 2,400 7,880g
2,700mm HLND-2700SW2 240W 27 2,756.3 2,700 8,840g
Note: Please contact our sales office for more details.
Inquiries via web site
Inquiries via phone
To Use HLND Series
· HLND Series requires the HLND dedicated cable(FCB-n-1.25SQ-ME7/FCB-20-2.0SQ-ME7) and power supply unit(PSB2-10024-EX/PSB2-30024-EX).
· The dedicated cable is available for a maximum length of 20 m. Since it cannot be extended, prepare a cable with a required length.
· When using the HLND Series linelight under normal light ON control, it is recommended to set the dimming control volume of the power supply unit to lower than the maximum volume to achieve the best performance with stability. Installing a heat dissipation plate to the line light unit is recommended for better efficiency.
· The HLND Series linelight unit may become hot when the dimming control volume on the power supply unit is set to HIGH under normal light ON control.