Specifications LNSP-series Common Specifications
Model LNSP- *** SW
“*** ” is the length of emitting surface. Available in 100 mm increments up to 1,000 mm.
Direct number 1500
Input voltage 24 VDC
LED color White
Correlated color temperature 5,800K
Connector SRCN1A16-7P Metal Connector (manufactured by Japan Aviation Electronics Industry, Limited)
Polarity and signals 1, 2, 3: (+) 4, 5, 6: (-) 7: NC
Cooling method Natural air cooling
Case material Emitting surface: Acrylic, Base: Aluminum alloy, Side plates: PC
Spectral distribution
Model-specific Specifications
Model
Power
consumption
(W)
Weight (g)
Dimensions (See dimensions diagrams.)
n
A:
Emitting surface (mm)
B: Overall length (mm)
(Not including cables.)
LNSP-100SW
21
430
1
100
126
LNSP-200SW
41
760
2
200
226
LNSP-300SW
61
1090
3
300
326
LNSP-400SW
81
1420
4
400
426
LNSP-500SW
101
1740
5
500
526
LNSP-600SW
121
2070
6
600
626
LNSP-700SW
142
2400
7
700
726
LNSP-800SW
162
2730
8
800
826
LNSP-900SW
182
3050
9
900
926
LNSP-1000SW
202
3380
10
1000
1026
Dimension Diagrams (mm) LNSP-(100*n)SW LED Light Unit Cables

These cables are used to connect LED Light Units to Control Units. Select from 2 m, 3 m, 5 m, 10 m, and 20 m lengths.

Direct number
3000142
3000151
3000159
3000131
3000149
Model
FCB-2-1.25SQ
-ME7
FCB-3-1.25SQ
-ME7
FCB-5-1.25SQ
-ME7
FCB-10-1.25SQ
-ME7
FCB-20-2.0SQ
-ME7
Cable length
2 m
3m
5 m
10 m
20 m
Dimension Diagrams (mm) FCB-n-1.25SQ-ME7 FCB-20-2.0SQ-ME7 Analog Unit Specifications
Model PSB3-30024
Direct number 2000762
Lighting method Constant lighting
Drive method Constant-voltage system
Light intensity control method Variable-voltage control
Number of channels 1 channel
Applicable Light Unit rating 24 V 300 W
Light intensity control Manual and external intensity control Front manual/external switch (MODE)
Variable output voltage range Select between 3 ranges via the front intensity range selector (RANGE).
  Manual Set any of 256 levels via the setting switch. Press and hold the switch for 2 seconds to lock the intensity value.
External Parallel communications 8-bit intensity value setting (B0 to B7) and write signal (WR)
Serial communications Command input via EIA-485 communications
Analog input Analog voltage (0 to 5 V)
External control mode can be selected by pushing the setting switch while turning ON the power to the Control Unit.
Lighting control Parallel bit input Lighting signal (OFF)
Serial communications Command input via EIA-485 communications
EIA-485
communications
settings
ID Set via the front ID switch (00 to 03).
Maximum of 4 connected Units.
Terminating resistance Set via the front ID switch
(terminating resistance is ON only when the ID is 00).
Lighting delay (typ.) 0.1s
Error detection display “Err” displayed on front-panel digital display
Error detection output Error is output and light output is stopped for internal AC/DC error.
External control
connector
Error output terminal (0C, 0E), photocoupler insulation,
open-collector output, alarm open (load current of less than
10 mA), and error status (serial communications)
Overcurrent protection Operation is restored automatically at 105% of the rated current.
Overvoltage protection Operation is restored when the power is turned ON again at 120% to 155% of the rated current.
Rated input voltage 100-240 VAC
Power consumption (typ.) 410VA
Frequency 50/60Hz
Inrush current (typ.) 20 A/40 A (primary/secondary value at 100 VAC), 40 A/40 A (primary/secondary value at 240 VAC)* From a cold start
Ground leakage current 3.5 mA max. (264 V AC, 60 Hz, with no load)
Output voltage
variation range (typ.)
Select between 3 ranges via the front intensity range selector.
12 to 24V *With no load.
15 to 24V *With no load.
18 to 24V *With no load.
Operating temperature and humidity Temperature: 0 to 40°C, Humidity: 20% to 85%RH (with no condensation)
Storage temperature and humidity Temperature: −20 to 60°C, Humidity: 20% to 85%RH (with no condensation)
Vibration resistance Acceleration: 19.6 m/s2, frequency: 10 to 55 Hz, cycles: 3 minutes, sweep cycle: for 1 hour each in X, Y, and Z directions
Cooling method Forced air cooling
CE Marking Conforms to safety standard EN 61010-1. / Conforms to EMC standard EN 61326-1, Class A.
Environmental regulations RoHS compliant
Material, coating, and surface processing Steel plate, thickness of cover: 1.0, thickness of chassis: 1.6, N3 leather tone finish
Weight 2,300 g max.
Accessories 2-meter long 3-prong power cord with ground terminal (1)
Dimension Diagrams (mm) External Control Cables

These cables are used for parallel communications, EIA-485 communications, and the analog input.

Parallel Communications CableON/OFF Input Cable
Parallel Communications and ON/OFF Input Branch CableAnalog Input Cable
EIA-485 Communications CableEIA-485 Communications Relay Cable
EIA-485 Communications Relay Cable