• Corporate Profile
  • Products & Services
  • Investor Relation
  • Contact us
for Machine Vision for Machine Vision

for Machine Vision

Information on New Products and Popular Products

Introducing newly developed products by combining the technology of CCS.

click here to download document
  • PD3 series
  • Product Summary
  • Lineup
  • PD3-3024-3
  • PD3-5024-4
  • PD3-10024-8
  • External
Compact and Easy to Use: 3-channel, 28-W Models PD3-3024-3series PD3-3024-3series Specifications Common Specifications
Lighting method Constant lighting/strobe lighting
Drive method Constant-voltage system
Light intensity control method PWM control and lighting time control
Number of channels 3 channels
Applicable Light Units (rated) 24V DC input, Total for all channels: 28 W
PWM frequency 125 kHz
Error detection display Front-panel digital OCP display
Overcurrent protection* Operates at 107% of rated output current or higher.
Reset by pressing operation setting switch for at least 1 second or by cycling the power supply.
Input voltage (rated) 100 to 240V AC
Power consumption (typ.) 78 VA
Frequency 50/60 Hz
Output voltage (rated) 24V DC
Output current (rated) Total for 3 channels: 1.1 A
Operating temperature and humidity Temperature: 0 to 40°C, Humidity: 20% to 85% (with no condensation)
Storage temperature and humidity Temperature: −20 to 60°C, Humidity: 20% to 85% (with no condensation)
Cooling method Natural air cooling
CE Marking Safety standard: Conforms to EN 61010-1, EMC standard: Conforms to EN 61326, Class A.
Material and surface processing Material: Aluminum and resin, Surface processing: Blue alumite
Weight 600 g max.
Accessories 2-m long 3-prong power cord with ground terminal

* Do not intentionally short-circuit the positive and negative output terminals.

PD3-3024-3-PI (Control Unit with Parallel Communications) Specifications
Direct number 2000775
Light intensity setting Manual Set to any of 256 levels on front-panel setting switch.
External 8-bit input (B0 to B7), write pulse (BRTWR), and channel selection (CHSEL0 to CHSEL2)
ON/OFF setting External trigger input
Lighting mode setting Manual Set to any of 11 levels on front-panel setting switch.
External 4-bit input (M0 to M3), write pulse (TRGWR), and channel selection (CHSEL0 to CHSEL2)
Error detection output NPN transistor output between pins 19 (OC) and 20 (OE) of external control connector
Normal: Open , Overcurrent output detected: Closed
External control connector Trigger input MIL connector, 10 pins
Lighting intensity/
Lighting mode setting
MIL connector, 20 pins
PD3-3024-3-SI ( Control Unit with EIA-485 Serial Communications ) Specifications
Direct number 2000777
Light intensity setting Manual Set to any of 256 levels on front-panel setting switch.
External Command input via EIA-485 communications
ON/OFF setting External trigger input or command input via EIA-485 communications
Lighting mode setting Manual Set to any of 11 levels on front-panel setting switch.
External Command input via EIA-485 communications
Error detection output Command sent when overcurrent output is detected.
External control connector Trigger input MIL connector, 10 pins
Lighting intensity/
Lighting mode setting
e-CON connector, 3 pins
PD3-3024-3-EI ( Control Unit with Ethernet Communications ) Specifications
Direct number 2000776
Light intensity setting Manual Set to any of 256 levels on front-panel setting switch.
External Command input via TCP/IP or UDP/IP communications
ON/OFF setting External trigger input or command input via TCP/IP or UDP/IP communications
Lighting mode setting Manual Set to any of 11 levels on front-panel setting switch.
External Command input via TCP/IP or UDP/IP communications
Error detection output Command sent when overcurrent output is detected.
External control connector Trigger input MIL connector, 10 pins
Lighting intensity/
Lighting mode setting
RJ-45 connector
Dimension Diagrams (mm) Dimension Diagrams (mm) Options External Control Cables
Parallel Communications Cable

This Cable is used for external control with parallel communications. The channel, light intensity setting, and lighting mode (constant mode, ON/OFF mode, or strobe mode) can be selected.

Direct number: 3000683 Model: EXCB2-M20-3
Trigger Input Cable

This cable is used to input an external trigger signal using parallel bits. The external trigger signal can be used to turn Light Units ON or OFF, or to flash the strobes.

Direct number: 3000682 Model: EXCB2-M10-3
EIA-485 Serial Communications Cable

This Cable is used for external control with EIA-485 communications. The channel, light intensity setting, ON/OFF setting, and lighting mode (constant mode, ON/OFF mode, or strobe mode) can be selected.

Direct number: 3000685 Model: EXCB2-E3-3
EIA-485 Serial Communications Relay Cable

This Cable is required to connect two or more PD3-series Control Units with EIA-485 communications.

Direct number: 3000721 Model: EXCB2-E3-E3-0.2
Parallel Communications/Trigger Input Branch Cable

This Cable includes the Parallel Communications Cable and the Trigger Input Cable in one cable.

Direct number: 3000684 Model: EXCB2-M10M20-3
Base Brackets

These Brackets are used to secure a PD3-series Control Unit to the floor, a shelve, or other surface.

* The Base Brackets are included with the PD3-5024-4 and PD3-10024-8 Control Units.

Direct number: 4001164 Model: BK-PD3