Introducing newly developed products by combining the technology of CCS.
| Series name | PFB2-20 | |||||||||
| Direct number | 6010 | |||||||||
| LED color | White | |||||||||
| Relative color temperature (typ.) | 6,000K | |||||||||
| Lighting method | Constant lighting | |||||||||
| Drive method | Constant-current system | |||||||||
| Light intensity control method | Variable current control | |||||||||
| Number of channels | 1 channel | |||||||||
| Lighting delay (max.) | 3,800 μs (ON time) | |||||||||
| Error detection | An error indicator lamp on the front panel flashes (0.5 s) and output stops if an error is detected. Error Details: • LED open failure detected • LED overheating detected • Fan shutdown detected (The output will not stop in this case.) • Microcontroller oscillator shutdown detected (1-s flashing) *Recovery is possible by cycling the power supply. |
|||||||||
| Input protection | Fuse | |||||||||
| Input voltage (rated) | DC24V | |||||||||
| Input voltage (range) | 21.6 to 26.4 V DC | |||||||||
| Power consumption (typ.) | 15W | |||||||||
| Operating environment | Temperature: 0 to 40°C, Humidity: 20% to 85%RH (with no condensation) | |||||||||
| Storage environment | Temperature: -20 to 60°C, Humidity: 20% to 85%RH (with no condensation) | |||||||||
| Cooling method | Forced air cooling, Intake vents: sides, Exhaust vents: rear | |||||||||
| CE marking | EMC standard: EN 61326-1 Class A compliant (PFB2-20SW-F-JT) | |||||||||
| Environmental regulations | RoHS compliant | |||||||||
| Material, coating, and surface processing |
|
|||||||||
| Weight | 1.2kg |
| Models | PFB2-20SW-F-SJT-xx (Specific model depends on light guide attachment adaptor.) |
| Control type | Serial |
| Light intensity control |
Manual: Continuous control using the light intensity control knob Remote: 256-step light intensity control via RS-232C communications commands (default: 0) *Minimum light intensity: Light intensity of approx. 6% to 7% (Control method selected using the remote/manual switch on the front panel.) |
| ON/OFF control | RS-232C communications commands |
| Lighting delay (max.) | 3,800 μs (ON time) |
| Error detection output |
An error command is returned via RS-232C communications. *Communications are disabled for a microcontroller oscillator shutdown error, so the only indication of the error is the flashing error indicator lamp. |
| CE marking | EMI standard: Complies with EN 61000-6-4, EMS standard: Complies with EN 61000-6-2 |
| Options | AD Adaptor: ADP2460-PFB-JT, External Control Cable: EXCB2-9-9-3-ST |
| Models | PFB2-20SW-F-PJT-xx (Specific model depends on light guide attachment adaptor.) |
| Control type | Parallel |
| Light intensity control |
Manual: Continuous control using the light intensity control knob Remote: 256-step light intensity control via external 8-bit parallel input *Minimum light intensity: Light intensity of approx. 6% to 7% (Control method selected using the remote/manual switch on the front panel.) |
| ON/OFF control | Via external control connector (Operates regardless of whether remote or manual control is selected.) |
| Lighting delay (max.) | 3,800 μs (ON time) |
| Error detection output |
15-pin D-sub, transistor output across 14-15 Normal operation: 14-15 OFF Error: 14-15 ON |
| CE marking | EMI standard: Complies with EN 61000-6-4, EMS standard: Complies with EN 61000-6-2 |
| Options | AD Adaptor: ADP2460-PFB-JT, External Control Cable: EXCB2-B3 |
| Models | PFB2-20SW-F-AJT-xx (Specific model depends on light guide attachment adaptor.) |
| Control type | Analog |
| Light intensity control |
Manual: Continuous control using the light intensity control knob Remote: Continuous analog light intensity control with a 0 to 5-V DC input voltage External variable resistor: Continuous intensity control with an external variable resistor *Minimum light intensity: Light intensity of approx. 6% to 7% (Control method selected using the remote/manual switch on the front panel.) Switched with external control connector (analog input voltage or external variable resistor). |
| ON/OFF control | Via external control connector (Operates regardless of whether remote or manual control is selected.) |
| Lighting delay (max.) | 3,800 μs (ON time) |
| Error detection output |
15-pin D-sub, transistor output across 14-15 Normal operation: 14-15 OFF Error: 14-15 ON |
| CE marking | EMI standard: Complies with EN 61000-6-4, EMS standard: Complies with EN 61000-6-2 |
| Options | AD Adaptor: ADP2460-PFB-JT, External Control Cable: EXCB2-B3 |