This Analog light control Unit is for the HLND, LT and LNSP Series Light Units. It operates on a 100 to 240V AC input. It has a measures 97 x 245 x 110mm (width x depth x height).
![]() | ![]() |
Download drawing files(PDF/DXF) from Here. | |
|
![]() |
| Direct Number | 2000762 | |
|---|---|---|
| Lighting Method | Constant lighting | |
| Drive Method | Constant-voltage system | |
| Light Control Method | Variable voltage control | |
| No. of Channels | 1Channel | |
| Applicable Light Units | 24V / 300W | |
| Light Control (Manual) |
Set with Manual/External Mode Selector. Manual:Setting switch rotated to set the light intensity to any of 256 levels. Setting switch pressed for at least 2s to lock the light intensity. |
|
| Light Control (Remote) |
External Parallel communications:8-bit light intensity setting (B0 to B7) and write signal (WR) Serial communications:Commands input with EIA-485 communications Analog input:Analog voltage (0 to +5 V) |
|
| Error Detection Display | Displays | |
| Error Detection Output | Error output and output stopped for internal ACDC error. External control connector:Error output terminals (OC and OE), photocoupler isolation, open-collector output, open in alarm (load current: 20 mA max.), and error status (serial communications) |
|
| Over Current Protection | Operates at 105% of the rated current. Reset automatically. | |
| Over Voltage Protection | Operates at 120 to 155% of the rated voltage. Reset when the power is turned ON again. | |
| Input Voltage (rating) |
100 to 240V AC | |
| Power Consumption (typ.) |
410VA | |
| Frequency | 50 / 60Hz | |
| Inrush Current (typ.) |
20A/40A ¡ÊFirst value/Second value at 100V AC¡Ë 40A/40A ¡ÊFirst value/Second value at 240V AC¡Ë Note : From a cold start | |
| Output Voltage (rating) |
24V DC | |
| External Control (input) |
15pin D-sub 1 : ON/OFF control input (OFF : +5V input), 2 : GND, 10 : analog light control input (0 to +5V), 11 : GND, 14 : +5V output (20mA max.), 8, 15 : GND |
|
| Output Connector | SRCN2A16-7SMetal connector [1, 2, 3 : output (+) / 4, 5, 6 : output (-) / 7 : NC] x 2 pieces and ELR-02V connector x 2 pieces | |
| External Control Connector | External control:One parallel communications connector (20-pin MIL-C-83503 compliant), one ON/OFF input connector (10-pin MIL-C-83503 compliant), and one EIA-485 communications/analog input connector (e-CON compliant) | |
| Cooling Method | Forced air cooling | |
| Material | Steel sheet, Cover thickness: 1.0 mm, Chassis thickness: 1.6 mm, N3 (leather tone) | |
| Operating Temperature and Humidity | Temperature : 0 to 40ºC, Humidity : 20 to 85%RH (No condensation) |
|
| Storage Temperature and Humidity | Temperature : -20 to 60ºC, Humidity : 20 to 85%RH (No condensation) |
|
| Dimensions | W 97mm x D 245mm x H 110mm | |
| Weight | 2300g | |
| Accessories | Instruction Guide x 1, 2m long 3-prong AC power cord with ground terminal x 1 | |
| Cable |
|
| Ctalog | C_PowerSupply_PSB3_e.pdf(PDF:498KB) |
|---|---|
| PDF Drawing | PSB3-30024_e.pdf(PDF:242KB) |
| DXF Drawing | PSB3-30024_e.dxf(DXF:816KB) |
| Pamphlet PDF | FL_PSB3_e.pdf(PDF:1666KB) |
| User Manual | M_PSB3_e.pdf(PDF:3573KB) |
| Connecting EIA-485 Communications Cables | PSB3_Connecting EIA-485 Communications Cables_eng.pdf(PDF:255KB) |
| 3D-CAD | Click to open download page for 3D-CAD. |
Note: You must log in from the Login Form to be able to download data that is available only to members of this website.
You can register from here if you are not a CCS member.
Quick Start Guide for downloading 3D CAD data.