IU Series LED lighting with Intensity Control Unit

Features IU Series

With the IU Series, you can change light intensity and perform light ON/OFF control without an external controller. 

  • The light intensity can be set to any of the 126 levels by adjusting the Intensity Control Unit
  • The IU Series has an M12 input connector, to which you can connect smart cameras and other devices to supply power

Specifications IU Series

Lighting method Continuous lighting
Drive method Constant-voltage system
Intensity control method PWM control
PWM frequency 125 kHz
Input voltage (rating) 24 VDC
Input voltage (range) 21.6 to 24 VDC
Input connector M 12 (4 pins, male)
Cable length 670 mm (including the Intensity Control Unit)

Dimensions Diagrams (Unit: mm) IU Series

figure1
pin left-bottom:1,right-bottom:2,right-top:3,left-top:4
Pin No. Signal
1 24 VDC*¹
2 NC
3 COMMON GND
4 ON/OFF input (+24 V)*²

*1 Voltage rating: 24 VDC, Voltage range: 21.6 to 24 VDC

  • The brightness of the Light Unit will be lower when the input voltage is less than 24 VDC.
  • Use a stable power source with an output voltage that does not fluctuate.

*2 Voltage rating: 24 VDC, Voltage range: 20 to 26.4 VDC

Line-up and Cables IU Series

Ring Lights

Model name Power consumption (typ.)
HPR2 HPR2-50RD-IU 8.1 W
HPR2-50SW-IU 9.6 W
HPR2-75RD-IU 11 W
HPR2-75SW-IU 11 W
HPR2-100RD-IU 11 W
HPR2-100SW-IU 11 W
HPR2-150RD-IU 11 W
HPR2-150SW-IU 11 W
LDR2 LDR2-32RD2-IU 2.0 W
LDR2-32SW2-IU 2.4 W
LDR2-42RD2-IU 2.5 W
LDR2-42SW2-IU 3.2 W
LDR2-50RD2-IU 3.6 W
LDR2-50SW2-IU 4.3 W
LDR2-70RD2-IU 6.6 W
LDR2-70SW2-IU 8.1 W
LDR2-90RD2-IU 11 W
LDR2-90SW2-IU 11 W
LDR2-50RD2-WD-IU 3.6 W
LDR2-70RD2-WD-IU 6.6 W
LDR2-90RD2-WD-IU 11 W
LFR LFR-100RD2-IU 4.1 W
LFR-100SW2-IU 5.1 W
LFR-130RD2-IU 5.1 W
LFR-130SW2-IU 6.2 W
LKR LKR-70RD2-IU 3.0 W
LKR-70SW2-IU 4.3 W
LDR-LA1 LDR-75RD2-LA1-IU 3.0 W
LDR-75SW2-LA1-IU 4.3 W
LDR-96RD2-LA1-IU 3.6 W
LDR-96SW2-LA1-IU 4.3 W
LDR-146RD2-LA1-IU 5.1 W
LDR-146SW2-LA1-IU 6.6 W
LDR-176RD2-LA1-IU 6.6 W
LDR-176SW2-LA1-IU 8.1 W
LDR-206RD2-LA1-IU 7.6 W
LDR-206SW2-LA1-IU 9.6 W
LDR2-LA LDR2-48RD2-LA-IU 2.5 W
LDR2-48SW2-LA-IU 3.6 W
LDR2-74RD2-LA-IU 5.1 W
LDR2-74SW2-LA-IU 6.2 W
LDR2-100RD2-LA-IU 9.6 W
LDR2-100SW2-LA-IU 11 W
LDR2-132RD2-LA-IU 11 W
LDR2-132SW2-LA-IU 11 W

Bar Lights

Model name Power consumption (typ.)
LDL2 LDL2-33X8RD2-IU 3.0 W
LDL2-33X8SW2-IU 2.5 W
LDL2-41X16RD2-IU 4.3 W
LDL2-41X16SW2-IU 4.3 W
LDL2-41X16RD2-WD-IU 4.3 W
LDL2-41X16SW2-WD-IU 4.3 W
LDL2-80X16RD2-IU 8.1 W
LDL2-80X16SW2-IU 8.1 W
LDL2-80X16RD2-WD-IU 8.1 W
LDL2-80X16SW2-WD-IU 8.1 W
LDL2-119X16RD2-IU 11 W
LDL2-119X16SW2-IU 11 W
LDL2-119X16RD2-WD-IU 11 W
LDL2-119X16SW2-WD-IU 11 W
LDL2-74X30RD2-IU 11 W
LDL2-74X30SW2-IU 11 W
LDL2-74X30RD2-WD-IU 11 W
LDL2-74X30SW2-WD-IU 11 W

Square Lights

Model name Power consumption (typ.)
FPQ2 FPQ2-32RD-IU 6.6 W
FPQ2-32SW-IU 5.6 W
FPQ2-48RD-IU 6.3 W
FPQ2-48SW-IU 11 W

Back Lights

Model name Power consumption (typ.)
TH2 TH2-27X27RD-IU 2.8 W
TH2-27X27SW-IU 3.4 W
TH2-43X35RD-IU 5.4 W
TH2-43X35SW-IU 5.3 W
TH2-51X51RD-IU 7 W
TH2-51X51SW-IU 8.7 W
TH2-63X60RD-IU 10.4 W
TH2-63X60SW-IU 10.2 W
TH2-83X75RD-IU 11 W
TH2-83X75SW-IU 11 W
LFL LFL-612RD2-P-IU 1.0 W
LFL-612SW2-P-IU 0.9 W
LFL-1012RD2-IU 1.0 W
LFL-1012SW2-IU 1.3 W
LFL-1012RD2-P-IU 1.0 W
LFL-1012SW2-P-IU 1.3 W
LFL-3212RD2-IU 2.0 W
LFL-3212SW2-IU 2.8 W
LFL-4012RD2-IU 2.5 W
LFL-4012SW2-IU 3.2 W
LFL-50RD2-IU 3.0 W
LFL-50SW2-IU 3.6 W
LFL-100RD2-IU 5.6 W
LFL-100SW2-IU 5.8 W

Dome Lights

Model name Power consumption (typ.)
HPD2 HPD2-75RD-IU 11 W
HPD2-75SW-IU 11 W
HPD2-100RD-IU 11 W
HPD2-100SW-IU 11 W
HPD2-150RD-IU 11 W
HPD2-150SW-IU 11 W

Flat Dome Lights

Model name Power consumption (typ.)
LFX3 LFX3-50RD-IU 11 W
LFX3-50SW-IU 11 W
LFX3-75RD-IU 11 W
LFX3-75SW-IU 11 W
LFX3-100RD-IU 11 W
LFX3-100SW-IU 11 W

Coaxial Lights

Model name Power consumption (typ.)
LFV3 LFV3-34RD-IU 4.2 W
LFV3-34SW-IU 3.7 W
LFV3-35RD-IU 3.6 W
LFV3-35SW-IU 4.2 W
LFV3-40RD-IU 5.1 W
LFV3-40SW-IU 5.1 W
LFV3-50RD-IU 8.6 W
LFV3-50SW-IU 11 W
LFV3-70RD-IU 11 W
LFV3-70SW-IU 11 W
LFV3-CP-13RD-IU 2.5 W
LFV3-CP-13SW-IU 2.8 W
LFV3-CP-18RD-IU 3.8 W
LFV3-CP-18SW-IU 4.6 W

Line-up and Cables IU Series

Model name: FRCB-n-M12-4M-4F (n=1, 2, 3)

This robot cable is used to extend the Light Unit cable length.
Cable length: 1 m, 2 m, 3 m

Line-up and Cables IU Series

Model name: FRCB-0.5-M12-AL-4M4F

This Adapter is used to continuously turn ON the Light Unit. A robot cable is used.
(Pins 1 and 4 are internally connected.)
Cable length: 0.5 m

For details of the products, please contact our branches shown below.

CCS America 6 Lincoln Knoll Lane, Suite 102, Burlington, MA. 01803, U.S.A.
TEL : +1-781-272-6900 / FAX : +1-781-272-6902
URL : http://www.ccsamerica.com/
e-mail : info@ccsamerica.com
CCS Europe Bergensesteenweg 421B, 1600 Sint-Pieters-Leeuw, Belgium
TEL : +32-(0)2-333-0080 / FAX : +32-(0)2-333-0081
e-mail : info@ccseu.com
CCS Asia 63 Hillview Avenue #07-10, Lam Soon Industrial Bldg Singapore 669569
TEL : +65-6769-1669 / FAX : +65-6769-3422
URL : http://www.ccs-asia.com.sg/
e-mail : sales@ccs-asia.com.sg