Visualizes nanometer-to-micrometer scale minute scratches, steps, surface irregularities, and subtle surface tilts.

Differential Interference Contrast Unit and Polarized Pupil Division Unit


Solving These Challenges

  • Want to observe nano- to micron-scale scratches and surface inclination components on specular workpieces with high contrast
  • Want to observe a wider area than is possible with a conventional differential interference contrast microscope
  • Want to inspect minute scratches, machining marks, and warping on glossy surfaces such as mirrors and wafers

Differential Interference Contrast Unit and Polarized Pupil Division Unit

The Differential Interference Contrast Unit and Polarized Pupil Division Unit enable visualization of nanometer-to-micrometer scale minute scratches, steps, surface irregularities, and subtle surface tilts that are difficult to detect with conventional imaging methods.

Built on proprietary technology that integrates the light and lens into a unified design, the unit delivers imaging performance optimized for machine vision.

Comparison of the Differential Interference Contrast Unit and Polarized Pupil Division Unit
Workpiece Differential Interference Contrast Unit Polarized Pupil Division Unit
Step Height Reference Sample (40 nm)

Step Height Reference Sample (40 nm)

Differential Interference Contrast Unit Images: The boundary of the step is clearly visible

The boundary of the step is clearly visible

Polarized Pupil Division Unit Images: The step can be clearly observed, but the edge is blurred

The step can be clearly observed, but the edge is blurred

鏡

Mirror

Differential Interference Contrast Unit Images: Tilt and surface undulation are only partially visible

Tilt and surface undulation are only partially visible

Polarized Pupil Division Unit Images: Gentle surface tilts and undulations are clearly visualized

Gentle surface tilts and undulations are clearly visualized

Differential Interference Contrast Unit

Differential Interference Contrast Unit MSU-1R5RD-CMODIC
Differential Interference Contrast Unit MSU-1R5RD-CMODIC
custom-order

Minute surface steps can be visualized by observing interference generated by the phase difference (optical path difference) of light reflected from two closely spaced points.

Features
  • Clearly visualizes minute scratches and irregularities
  • Enables imaging with a wider field of view than conventional differential interference contrast microscopes
Application Example
  • Inspection for minute scratches and marks on glossy surfaces
  • Detection of scratches, cracks, and crystal defects on wafers
Imaging Example
Sapphire substrate*
Imaging Example: Sapphire substrate (30 nm laser grooving) Minute height differences are clearly captured

Minute height differences are clearly captured
*30 nm laser grooving

Wafer Scratches
Imaging Example: Wafer Scratches  Visualize minute scratches

Visualize minute scratches

Polarized Pupil Division Unit

Polarized Pupil Division Unit MSU-1R5RD-CMOPPD
Polarized Pupil Division Unit
MSU-1R5RD-CMOPPD
REACH pending (as of October 2026) custom-order

A proprietary polarization element detects changes in polarization caused by surface inclination, enabling visualization of even subtle tilts and undulations

Features
  • Visualizes subtle surface tilts and undulations using a unique polarization element
  • Capable of imaging with a field of view of up to approximately 110 mm (0.1x optical magnification)
Application Example
  • Inspection of fine undulations and inclinations on glossy surfaces, as well as detection of wafer polishing marks, warping, and machining marks
Wafer Backside

Machining-induced undulations and machining marks are imaged as white areas

Workpiece: Wafer Backside Machining-induced undulations and machining marks
are imaged as white areas

Common Specifications

Please refer to the downloadable materials for specifications and dimensional drawings.

Optical Magnification Can Be Customized

Optical Magnification Can Be Customized

The optical magnification can be customized, including changing the sensor size to 1.1 inch and the optical magnification to 1.0x. Contact us for details.

Available Optical Magnification Options
Differential Interference Contrast Unit 1.0x 1.5x 4.125x 8.25x 16.5x
Polarized Pupil Division Unit 0.1x 0.8x 1.0x 1.5x 4.125x